BLJMZ - NITROGEN, G-7

  • MSDS: BLJMZ
  • Manufacturer: AIRCO
  • Product Name: NITROGEN, G-7
  • National Stock Number: 6830-01-126-6849
Product Identification

Product ID:NITROGEN, G-7
MSDS Date:08/15/1989
FSC:6830
NIIN:01-126-6849
MSDS Number: BLJMZ

Responsible Party
AIRCO
575 MOUNTAIN AVE
MURRAY HILL, NJ 07974
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 201-464-8100

Cage: AIRCO

Contractor
AIRCO INC, AIRCO INDUSTRIAL GASES DIV.
MURRAY HILL, NJ 07974-2006 US

Telephone: 800-424-9300(CHEMTREC)

Cage: 00741

Ingredients

NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: SEE ING

ACGIH TLV: ASPHYXIANT; 9192


OPEN EYELIDS WIDE TO ALLOW LIQ TO EVAP. IF PAIN

RTECS: 9999999ZZ


TREATMENT & FOLLOW UP. IF VICTIM CANNOT TOLERATE

RTECS: 9999999ZZ


FEDERAL, STATE & LOCAL REGULATIONS .

RTECS: 9999999ZZ


USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT

RTECS: 9999999ZZ


STORE IN COOL, DRY, WELL-VENTED AREA OF NON-COMBUST

RTECS: 9999999ZZ


EXITS. DO NOT ALLOW TEMP WHERE CYLS ARE STORED TO

RTECS: 9999999ZZ


SECURED TO PVNT FALLING/BEING KNOCKED OVER. USE FIRST

RTECS: 9999999ZZ


STORED FOR EXCESSIVE PERIODS OF TIME. NEVER CARRY

RTECS: 9999999ZZ


ENCLSD SPACE SUCH AS CAR TRUNK/VAN/STATION WAGON.

RTECS: 9999999ZZ


IS NON-CORR & MAY BE USED W/ANY COMMON STRUCTURAL

RTECS: 9999999ZZ


BY QUALIFIED PRDCER OF COMPRESSED GASES. SHIPMENTS

RTECS: 9999999ZZ


OWNER OR W/HIS (WRITTEN) CONSENT, IS VIOLATION OF

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EFTS OF OVEREXP TO HIGH CONC MAY
INCL LOSS OF BAL/DIZZ, TIGHTNESS IN FRONTAL AREA OF FOREHEAD,
TINGLING OF TONGUE/FINGERTIPS/TOES, WEAK SPEECH LEADING TO
INABLILITY TO UTTER SOUNDS, RAPID REDUCT ION IN ABILITY TO PERFORM
MOVEMENTS, REDUCED CONSCIOUSNESS OF SURROUNDINGS, LOSS OF TACTILE
SENSATIONS,(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:HEIGHTENED MENTAL ACTIVITY. NITROGEN
IS NONTOX BUT LIBERATION OF LG AMT IN CONFINED AREA COULD DISPLACE
AMT OF O*2 IN AIR NEC TO SUPPORT LIFE. POSS THAT NONE OF SYMPS MAY
OCCUR IN NITROGEN AS PHY SO THERE MAY BE NO DEFINITE WARNINGS.
SKIN:CNTCT W/LIQ PROD MAY CAUSE FROSTBT. EYES:CNTCT W/LIQ MAY CAUSE
TISS FRZG.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP. RESCUE
PERS SHOULD BE EQUIPPED W/NIOSH/MSHA APPRVD SCBA. INHAL:PERS SHOULD
BE ASSISTED TO UNCONTAM AREA IMMED IF CONSCIOUS, INHAL FRESH AIR,
IF UN CON, GIVE ARTF RESP & SUPP O*2. FURTHERTREATMENT SHOULD BE
SYMPTOMATIC & SUPPORTIVE. SKIN:FOR DERM CNTCT/FROSTBT:REMOVE CONTAM
CLTHG & FLUSH AFFECTED AREA W/LUKEWARM H*2O. DO NOT USE HOT
(SUPDAT)

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:NONFLAMMABLE, INERT GAS. USE MEDIA SUITABLE FOR
SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREAS. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CNTNR/CNTNR VALVE, CNTCT CHE MTREC FOR EMER ASSIST/CALL CLOSEST
MFR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY IN WELL VENTED AREAS. VALVE
PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE PROT
OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG/SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK
FOR CYL MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL
TO LOWER PRESS(<3000PSIG)PIPING/SYS. DO NOT HEAT CYL BY ANY MEANS
TO INCR DISCHA RGE OF RATE OF PROD FROM CYL. (ING 5)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
WITH MASK OR NIOSH/MSHA APPROVED SCBA SHOULD BE AVAILABLE FOR
EMERGENCY USE.
Ventilation:LOCAL EXHAUST TO PREVENT ACCUMULATION OF HIGH
CONCENTRATIONS SO AS TO REDUCE O*2 LEVEL IN AIR TO LESS THAN 19.5%.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOES. EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:>CRITICAL TEMP. FIRST AID PROC:H*20. SEE MD IMMED IF CRYOGENIC BURN
HAS RESULTED IN BLISTERING OF DERM SURFS/DEEP TISS FRZG. EYES:NEVER
INTRODUCE OINTMENT/OIL W/OUT MED ADVICE. IN CASE OF FRZG/CRYO GENIC
BURNS CAUSED BY RAPIDLY EVAP LIQ,DO NOT WASH W/HOT/EVEN TEPID H*2O!
REMOVE VICTIM FROM SOURCE OF CONTAM. (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Pres:SUPP DATA
Vapor Density:0.97
Solubility in Water:VERY SLIGHTLY SOL
Appearance and Odor:COLORLESS, ODORLESS GAS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS.
RETURN IN SHIPPING CNTNR PROPERLY LBLED, W/ANY VALVE OUTLET
PLUGS/CAPS SECURED & VALVE PROT CAP IN PLACE TO MFR FOR PROPER
DISP. FOR EMER DISP, CNTCT CLOSE ST MFR/CALL CHEMTREC. DISP MUST BE
I/A/W (ING 4)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.